Home     Sopravvivere Nell'Universo    
Services
    Perché adottare     Donatori     Astro Foto     La collezione     Forum     Blog New!     FAQ     Login  
→ Adopt this star  

HD 119193


Contenuti

Immagini

Carica la tua immagine

DSS Images   Other Images


Articoli relazionati

The limb darkening of α Centauri B. Matching 3D hydrodynamical models with interferometric measurements
For the nearby dwarf star α Cen B (K1 V), we presentlimb-darkening predictions from a 3D hydrodynamical radiative transfermodel of its atmosphere. We first compared the results of this model toa standard Kurucz's atmosphere. Then we used both predictions to fit thenew interferometric visibility measurements of α Cen B obtainedwith the VINCI instrument of the VLT Interferometer. Part of these newvisibility measurements were obtained in the second lobe of thevisibility function, which is sensitive to stellar limb-darkening. Thebest agreement is found for the 3D atmosphere limb-darkening model and alimb-darkened angular diameter of θ_3D = 6.000± 0.021 mas,corresponding to a linear radius of 0.863 ± 0.003 R_ȯ(assuming π = 747.1 ± 1.2 mas). Our new linear radius agreeswell with the asteroseismic value predicted by Thévenin et al.(2002, A&A, 392, L9). In view of future observations of this starwith the VLTI/AMBER instrument, we also present limb-darkeningpredictions in the J, H, and K bands.

First results from the ESO VLTI calibrators program
The ESO Very Large Telescope Interferometer (VLTI) is one of the leadinginterferometric facilities. It is equipped with several 8.2 and 1.8 mtelescopes, a large number of baselines up to 200 m, and with severalsubsystems designed to enable high quality measurements and to improvesignificantly the limits of sensitivities currently available tolong-baseline interferometry. The full scientific potential of the VLTIcan be exploited only if a consistent set of good quality calibrators isavailable. For this, a large number of observations of potentialcalibrators have been obtained during the commissioning phase of theVLTI. These data are publicly available. We briefly describe theinterferometer, the VINCI instrument used for the observations, the dataflow from acquisition to processed results, and we present and commenton the volume of observations gathered and scrutinized. The result is alist of 191 calibrator candidates, for which a total of 12 066observations can be deemed of satisfactory quality. We present a generalstatistical analysis of this sample, using as a starting point theangular diameters previously available in the literature. We derive thegeneral characteristics of the VLTI transfer function, and its trendwith time in the period 2001 through mid-2004. A second paper will bedevoted to a detailed investigation of a selected sample, aimed atestablishing a VLTI-based homogeneous system of calibrators.

CHARM2: An updated Catalog of High Angular Resolution Measurements
We present an update of the Catalog of High Angular ResolutionMeasurements (CHARM, Richichi & Percheron \cite{CHARM}, A&A,386, 492), which includes results available until July 2004. CHARM2 is acompilation of direct measurements by high angular resolution methods,as well as indirect estimates of stellar diameters. Its main goal is toprovide a reference list of sources which can be used for calibrationand verification observations with long-baseline optical and near-IRinterferometers. Single and binary stars are included, as are complexobjects from circumstellar shells to extragalactic sources. The presentupdate provides an increase of almost a factor of two over the previousedition. Additionally, it includes several corrections and improvements,as well as a cross-check with the valuable public release observationsof the ESO Very Large Telescope Interferometer (VLTI). A total of 8231entries for 3238 unique sources are now present in CHARM2. Thisrepresents an increase of a factor of 3.4 and 2.0, respectively, overthe contents of the previous version of CHARM.The catalog is only available in electronic form at the CDS viaanonymous ftp to cdsarc.u-strasbg.fr (130.79.128.5) or via http://cdsweb.u-strasbg.fr/cgi-bin/qcat?J/A+A/431/773

J - K DENIS photometry of a VLTI-selected sample of bright southern stars
We present a photometric survey of bright southern stars carried outusing the DENIS instrument equipped with attenuating filters. Theobservations were carried out not using the survey mode of DENIS, butwith individual target pointings. This project was stimulated by theneed to obtain near-infrared photometry of stars to be used in earlycommissioning observations of the ESO Very Large TelescopeInterferometer, and in particular to establish a network of brightcalibrator sources.We stress that near-infrared photometry is peculiarly lacking for manybright stars. These stars are saturated in 2MASS as well as in regularDENIS observations. The only other observations available for brightinfrared stars are those of the Two Micron Sky Survey dating from overthirty years ago. These were restricted to declinations above≈-30°, and thus cover only about half of the sky accessible fromthe VLTI site.We note that the final 2MASS data release includes photometry of brightstars, obtained by means of point-spread function fitting. However, thismethod only achieves about 30% accuracy, which is not sufficient formost applications.In this work, we present photometry for over 600 stars, each with atleast one and up to eight measurements, in the J and K filters. Typicalaccuracy is at the level of 0\fm05 and 0\fm04 in the J and K_s bands,respectively.Based on observations collected at the European Southern Observatory, LaSilla.Tables 1 and 2 are only available in electronic form at the CDS viaanonymous ftp to cdsarc.u-strasbg.fr (130.79.128.5) or viahttp://cdsweb.u-strasbg.fr/cgi-bin/qcat?J/A+A/413/1037

Hipparcos red stars in the HpV_T2 and V I_C systems
For Hipparcos M, S, and C spectral type stars, we provide calibratedinstantaneous (epoch) Cousins V - I color indices using newly derivedHpV_T2 photometry. Three new sets of ground-based Cousins V I data havebeen obtained for more than 170 carbon and red M giants. These datasetsin combination with the published sources of V I photometry served toobtain the calibration curves linking Hipparcos/Tycho Hp-V_T2 with theCousins V - I index. In total, 321 carbon stars and 4464 M- and S-typestars have new V - I indices. The standard error of the mean V - I isabout 0.1 mag or better down to Hp~9 although it deteriorates rapidly atfainter magnitudes. These V - I indices can be used to verify thepublished Hipparcos V - I color indices. Thus, we have identified ahandful of new cases where, instead of the real target, a random fieldstar has been observed. A considerable fraction of the DMSA/C and DMSA/Vsolutions for red stars appear not to be warranted. Most likely suchspurious solutions may originate from usage of a heavily biased color inthe astrometric processing.Based on observations from the Hipparcos astrometric satellite operatedby the European Space Agency (ESA 1997).}\fnmsep\thanks{Table 7 is onlyavailable in electronic form at the CDS via anonymous ftp tocdsarc.u-strasbg.fr (130.79.128.5) or viahttp://cdsweb.u-strasbg.fr/cgi-bin/qcat?J/A+A/397/997

New periodic variables from the Hipparcos epoch photometry
Two selection statistics are used to extract new candidate periodicvariables from the epoch photometry of the Hipparcos catalogue. Theprimary selection criterion is a signal-to-noise ratio. The dependenceof this statistic on the number of observations is calibrated usingabout 30000 randomly permuted Hipparcos data sets. A significance levelof 0.1 per cent is used to extract a first batch of candidate variables.The second criterion requires that the optimal frequency be unaffectedif the data are de-trended by low-order polynomials. We find 2675 newcandidate periodic variables, of which the majority (2082) are from theHipparcos`unsolved' variables. Potential problems with theinterpretation of the data (e.g. aliasing) are discussed.

A catalogue of calibrator stars for long baseline stellar interferometry
Long baseline stellar interferometry shares with other techniques theneed for calibrator stars in order to correct for instrumental andatmospheric effects. We present a catalogue of 374 stars carefullyselected to be used for that purpose in the near infrared. Owing toseveral convergent criteria with the work of Cohen et al.(\cite{cohen99}), this catalogue is in essence a subset of theirself-consistent all-sky network of spectro-photometric calibrator stars.For every star, we provide the angular limb-darkened diameter, uniformdisc angular diameters in the J, H and K bands, the Johnson photometryand other useful parameters. Most stars are type III giants withspectral types K or M0, magnitudes V=3-7 and K=0-3. Their angularlimb-darkened diameters range from 1 to 3 mas with a median uncertaintyas low as 1.2%. The median distance from a given point on the sky to theclosest reference is 5.2degr , whereas this distance never exceeds16.4degr for any celestial location. The catalogue is only available inelectronic form at the CDS via anonymous ftp to cdsarc.u-strasbg.fr(130.79.128.5) or viahttp://cdsweb.u-strasbg.fr/cgi-bin/qcat?J/A+A/393/183

CHARM: A Catalog of High Angular Resolution Measurements
The Catalog of High Angular Resolution Measurements (CHARM) includesmost of the measurements obtained by the techniques of lunaroccultations and long-baseline interferometry at visual and infraredwavelengths, which have appeared in the literature or have otherwisebeen made public until mid-2001. A total of 2432 measurements of 1625sources are included, along with extensive auxiliary information. Inparticular, visual and infrared photometry is included for almost allthe sources. This has been partly extracted from currently availablecatalogs, and partly obtained specifically for CHARM. The main aim is toprovide a compilation of sources which could be used as calibrators orfor science verification purposes by the new generation of largeground-based facilities such as the ESO Very Large Interferometer andthe Keck Interferometer. The Catalog is available in electronic form atthe CDS via anonymous ftp to cdsarc.u-strasbg.fr (130.79.128.5) or viahttp://cdsweb.u-strasbg.fr/cgi-bin/qcat?J/A+A/386/492, and from theauthors on CD-Rom.

Spectral Irradiance Calibration in the Infrared. X. A Self-Consistent Radiometric All-Sky Network of Absolutely Calibrated Stellar Spectra
We start from our six absolutely calibrated continuous stellar spectrafrom 1.2 to 35 μm for K0, K1.5, K3, K5, and M0 giants. These wereconstructed as far as possible from actual observed spectral fragmentstaken from the ground, the Kuiper Airborne Observatory, and the IRAS LowResolution Spectrometer, and all have a common calibration pedigree.From these we spawn 422 calibrated ``spectral templates'' for stars withspectral types in the ranges G9.5-K3.5 III and K4.5-M0.5 III. Wenormalize each template by photometry for the individual stars usingpublished and/or newly secured near- and mid-infrared photometryobtained through fully characterized, absolutely calibrated,combinations of filter passband, detector radiance response, and meanterrestrial atmospheric transmission. These templates continue ourongoing effort to provide an all-sky network of absolutely calibrated,spectrally continuous, stellar standards for general infrared usage, allwith a common, traceable calibration heritage. The wavelength coverageis ideal for calibration of many existing and proposed ground-based,airborne, and satellite sensors, particularly low- tomoderate-resolution spectrometers. We analyze the statistics of probableuncertainties, in the normalization of these templates to actualphotometry, that quantify the confidence with which we can assert thatthese templates truly represent the individual stars. Each calibratedtemplate provides an angular diameter for that star. These radiometricangular diameters compare very favorably with those directly observedacross the range from 1.6 to 21 mas.

Luminosity and Temperature from Near-Infrared Spectra of Late-Type Giant Stars
We present moderate resolution (lambda / Delta lambda ~ 1380 and lambda/ Delta lambda ~ 4830) spectra of 43 K0 to M6 III stars covering 2.19 -2.34 mu m and measure equivalent widths of the strongest absorptionfeatures - Na I, Ca I, and (12) CO(2,0) - present on the spectra. Thehigh resolution Wallace & Hinkle (1996) spectral atlas shows thatour moderate resolution measurements of the atomic features havesignificant contributions from other species, such as Sc, S, Fe, Ti, Si,and V. We also find that our measured equivalent widths are affected byCN absorption present in the continuum bands. In spite of this, theequivalent widths of Na I and Ca I features at moderate resolution stillshow a strong dependence on effective temperature. The CO equivalentwidth at moderate resolution is less affected by other lines andcontinuum placement than the atomic features, because of its relativelygreater strength. We compare our data to similar data taken forlate-type dwarf stars (Ali et al. 1995) and find that a two dimensionalspectral classification can be constructed based on the near-IR spectra.The quantity log[EW(CO)/(EW(Na)+EW(Ca))] is a strong luminosityindicator independent of effective temperature, while the equivalentwidth of (12) CO(2,0) has a well-defined dependence on effectivetemperature for a given luminosity. This two dimensional spectralclassification is ideal for cool stars obscured by dust in, for example,the central part of the Galactic bulge and regions of star formation.

Asymptotic giant branch stars near the sun
Available red and near-infrared photometry and apparent motions of M, S,and C asymptotic giant branch (AGB) stars in the Bright Star Catalogueare tabulated and discussed. It is shown that the red and near infraredindices normally used for late-type stars are interchangeable except forcarbon stars. The M-type giants are variable with visual amplitudegreater than 0.05 mag. The reddening-free parameter m2 from Genevaphotometry is essentially a temperature parameter for M giants, whilethe reddening-free parameter d is a sensitive detector of blue stellarcompanions. The space density of AGB stars near the sun decreases by afactor of 35 in a temperature range 3800 to 3400 K. Two of the S starsnear the sun were found to have nearly equal space motions and may becomembers of the Arcturus group.

Walraven photometry of nearby southern OB associations
Homogeneous Walraven (VBLUW) photometry is presented for 5260 stars inthe regions of five nearby southern OB associations: Scorpio Centaurus(Sco OB2), Orion OB1, Canis Major OB1, Monoceros OB1, and Scutum OB2.Derived V and (B - V) in the Johnson system are included.

Radial velocities of southern stars obtained with the photoelectric scanner CORAVEL. III - 790 late-type bright stars
Abstract image available at:http://adsabs.harvard.edu/cgi-bin/nph-bib_query?1985A&AS...59...15A&db_key=AST

Variable and Potential Variable Stars in the Bright Star Catalogue
Not Available

Sottometti un nuovo articolo


Link relazionati

  • - Nessun link trovato -
Sottometti un nuovo link


Membro dei seguenti gruppi:


Osservazione e dati astrometrici

Costellazione:Centauro
Ascensione retta:13h42m54.60s
Declinazione:-50°47'26.0"
Magnitudine apparente:6.41
Distanza:290.698 parsec
Moto proprio RA:-9.4
Moto proprio Dec:-15.6
B-T magnitude:8.623
V-T magnitude:6.617

Cataloghi e designazioni:
Nomi esatti
HD 1989HD 119193
TYCHO-2 2000TYC 8274-385-1
USNO-A2.0USNO-A2 0375-18932172
BSC 1991HR 5152
HIPHIP 66923

→ Richiesta di ulteriori cataloghi da VizieR