Contents
Images
Upload your image
DSS Images Other Images
Related articles
Hipparcos red stars in the HpV_T2 and V I_C systems For Hipparcos M, S, and C spectral type stars, we provide calibratedinstantaneous (epoch) Cousins V - I color indices using newly derivedHpV_T2 photometry. Three new sets of ground-based Cousins V I data havebeen obtained for more than 170 carbon and red M giants. These datasetsin combination with the published sources of V I photometry served toobtain the calibration curves linking Hipparcos/Tycho Hp-V_T2 with theCousins V - I index. In total, 321 carbon stars and 4464 M- and S-typestars have new V - I indices. The standard error of the mean V - I isabout 0.1 mag or better down to Hp~9 although it deteriorates rapidly atfainter magnitudes. These V - I indices can be used to verify thepublished Hipparcos V - I color indices. Thus, we have identified ahandful of new cases where, instead of the real target, a random fieldstar has been observed. A considerable fraction of the DMSA/C and DMSA/Vsolutions for red stars appear not to be warranted. Most likely suchspurious solutions may originate from usage of a heavily biased color inthe astrometric processing.Based on observations from the Hipparcos astrometric satellite operatedby the European Space Agency (ESA 1997).}\fnmsep\thanks{Table 7 is onlyavailable in electronic form at the CDS via anonymous ftp tocdsarc.u-strasbg.fr (130.79.128.5) or viahttp://cdsweb.u-strasbg.fr/cgi-bin/qcat?J/A+A/397/997
| Ca II H and K Filter Photometry on the UVBY System. II. The Catalog of Observations Abstract image available at:http://adsabs.harvard.edu/cgi-bin/nph-bib_query?1995AJ....109.2828T&db_key=AST
| Preliminary UVBY calibrations for G and K type dwarf stars Four-color uvby photometry for several hundred late-type dwarf stars oftypes G, K and M is discussed. Mean values of photometric indices aregiven for MK spectral types between F8/G0V and M2V. Preliminary standardrelations between the four-color indices are derived. Based onparallaxes and results from high-dispersion spectroscopic analyses,calibrations of the observed indices in terms of Mv, log Te and Fe/Hhave been derived. The means errors are 0.29 mag, 0.009 dex, and 0.17dex, respectively. The calibrations are valid for class-V stars of allpopulations between G0 and M2. If extreme population-II dwarfs areexcluded, the mean error of the abundance calibration decreases to 0.13dex. Calibrations in terms of log g have been attempted,, but the lowaccuracy of the spectroscopic g determinations does not inspireconfidence in the results. The possible contribution of a'fourth-parameter' variation to the mean errors of the calibrations isbriefly discussed. This fourth parameter could be the intrinsic heliumabundance of the stars.
| Photoelectric measurements of lunar occultations. VIII Photoelectric timings are reported for 276 lunar occultation eventswhich were observed between March 1975 and February 1976. The timings(in UTC) are based on Loran G equipment of a lunar laser-ranging groupor on WWV signals. Angular diameters are determined for HR 5301, HD176124, Chi-1-Orionis, and HR 601. Twenty cases of possible or actualdouble stars, including Beta Capricorni, are noted along with oneprobable triple system (51 Piscium). Several technical and computationaldifficulties encountered in this program are discussed.
|
Submit a new article
Related links
Submit a new link
Member of following groups:
|
Observation and Astrometry data
Constellation: | しし座 |
Right ascension: | 11h08m23.58s |
Declination: | -00°50'26.6" |
Apparent magnitude: | 7.482 |
Distance: | 892.857 parsecs |
Proper motion RA: | -41.2 |
Proper motion Dec: | -8.2 |
B-T magnitude: | 9.48 |
V-T magnitude: | 7.647 |
Catalogs and designations:
|